Checksheet Status Board
Dashboard / CM / NSW LEAK TEST / YFG00 / Setup approval #2058
Total parameters7checked
Live3within limits
NG4out of limits
Live %3 of 7 parameters
Setup approval
Result #2058 · NSW LEAK TEST · YFG00OK
- Done by
- Site Admin
- When
- 15 Dec 2023, 14:1215 Dec 2023
- Parameters
- 3 OK · 4 NG of 7
Every parameter in this record
| # | Parameter | Specification | Technique | Actual | Limits (LSL – USL) | Result |
|---|---|---|---|---|---|---|
| 10 | Fin Height | 5.62±0.05MM | Manual Entry | 5.62 | — | OK |
| 11 | Tank to Tank | 629.6±1.5MM | Manual Entry | 629.6 | — | OK |
| 12 | Header to Fin Gap | Less Than 5MM | Manual Entry | 5 | — | OK |
| 13 | Fin Condition | Fin Straight/No lean | Visual | — | — | NG |
| 14 | HDR CLAMP Condition | OK Condition | Visual | — | — | NG |
| 15 | Wrap UP sensor | OK Condition | Visual | — | — | NG |
| 15 | Wrap UP sensor | OK Condition | Visual | — | — | NG |